Assistance 4D probe; recognize the probe by way of the ID code; change the 4D generate signal through the electrical relay to generate the 4D probe operate Typically. 4.2.2 Major board The main board can be divided into two pieces: entrance-conclude of the primary board and back-finish of the key board.
Highest four situations tasking for one transmitted beam, resulting in fantastic time resolution and higher body level.
Notice: On the keep an eye on, the brightness adjustment will come ahead of distinction. Right after readjusting the monitor’s contrast and brightness, alter all preset and peripheral options.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
By continuing your go to on our Web page, you happen to be consenting to our utilization of cookies. However, you are able to change your cookie options at any time. Cookie preference Acknowledge and Proceed
If you halt the scanning and also the graphic capture, it is best to energy off the method and disconnect the system with the AC power supply, then pull out AC electric power cables. Site 109: Battery Connecting Board
S. ought to provide the Division with the e-mail tackle if they have a person. The e-mail supplied may very well be employed for official conversation Together with the licensee. However email addresses are public document. If you do not want to provide a private handle, remember to offer the Department with the email tackle which may be created available to the public. Make sure you see our Chapter 455 page to determine If you're impacted by this transformation.
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Assessing patients in currently’s demanding setting involves ground breaking technological innovation that enables clinicians to create speedy and assured diagnoses. The flexibility on the DP-50 expands your medical utility though assisting to enhance affected individual care.
five.two.three Geometric positioning accuracy Longitudinal geometric positioning precision Exam Stage: Do adjustments as just how in testing the maximum depth. File the distance by 20mm Just about every phase within the longitudinal targets line utilizing the measurement caliper; Find the worth with the best mistake (to 20mm), compute the accuracy using the method underneath The measurement caliper need to be positioned for the higher edge of the concentrate on, NOTE:... Website page seventy nine Transverse geometric positioning accuracy Test Move: Protect the scan floor of your phantom with water or couple gel, Carefully Get hold of the probe Along with the scan area Change the depth, making the transverse targets to be exhibited from the impression. Modify the main target place to get posited beside the transverse targets (the common just isn't distinct) Alter parameters like attain, TGC, building Each individual transverse targets for being clearly exhibited. Webpage 80 five.5.2.four Blackout Location Check Action: Go over the scan area on the phantom with h2o or couple gel, Carefully contact the probe with the scan floor Regulate the depth at a decreased benefit, and set the main target at the nearest spot to the scan surface. Lessen the worth of parameters like AP, Get until the track record noise just is usually found. Web site 81: Program Upgrade And Upkeep
The DP-fifty Expert is definitely an ground breaking, substantial-performance Ultrasound Technique engineered to assist you to obtain the insights you would like. The Procedure’s effective engine and high-speed processing offer outstanding image quality and a whole info management Answer.
.. Webpage 161 The indicator around the printer Faults occur when the adapter turns orange, along with the printing printer adapter runs. Disconnect and hook up the fails. electricity adapter, electric power over the printer adapter again, and validate whether the printing is ordinary after 1 minute. Page 163: Electrical Security Inspection
Observe: Prior to inserting the connector to the probe port, inspect the connector pin. If the pin is bent, usually do not make use of the probe right until it's been inspected / fixed / changed. Putting in Peripherals For the designs on the supported peripherals, remember to seek advice from “two.
Mindray respects your privateness. We use cookies for a number of reasons, for instance website functionality, enhancing your knowledge of our Internet site, making integration with social websites Dp50rb and serving to goal our marketing.
Be aware: Be sure that you may pull out and push into your IO board sockets vertically when pulling out and assembling the IO board assembly to the placement of the tackle. Take away panhead screws with washers M3X6 (four) accustomed to protected the IO board, after which you can acquire out the IO board. Webpage 116 Remove panhead screws with washers (2 M3X6) which might be set on the leading device, consider out the upper baffle after which you can pull out two cables connecting the key board to the ability module assembly.